Search results
Results from the WOW.Com Content Network
The upstream static pressure (1) is higher than in the constriction (2), and the fluid speed at "1" is lower than at "2", because the cross-sectional area at "1" is greater than at "2". A flow of air through a pitot tube Venturi meter, showing the columns connected in a manometer and partially filled with water. The meter is "read" as a ...
The calculation of the pressure drop along the individual pipes of a gas network requires use of the flow equations. Many gas flow equations have been developed and a number have been used by the gas industry. Most are based on the result of gas flow experiments.
If the fluid is a liquid, a different type of limiting condition (also known as choked flow) occurs when the venturi effect acting on the liquid flow through the restriction causes a decrease of the liquid pressure beyond the restriction to below that of the liquid's vapor pressure at the prevailing liquid temperature.
[4] [5] [6] A generalized model of the flow distribution in channel networks of planar fuel cells. [6] Similar to Ohm's law, the pressure drop is assumed to be proportional to the flow rates. The relationship of pressure drop, flow rate and flow resistance is described as Q 2 = ∆P/R. f = 64/Re for laminar flow where Re is the Reynolds number.
Pressure has dimensions of energy per unit volume, therefore the pressure drop between two points must be proportional to the dynamic pressure q. We also know that pressure must be proportional to the length of the pipe between the two points L as the pressure drop per unit length is a constant.
In fluid dynamics, pipe network analysis is the analysis of the fluid flow through a hydraulics network, containing several or many interconnected branches. The aim is to determine the flow rates and pressure drops in the individual sections of the network.
Pressure drop (Δp) Liquid-to-gas ratio (L/G) Liquid-inlet pressure (p L) Removal efficiency: Applications: Gases: 1.3–13 cm of water 7-13 L/m 3: 100-830 kPa 95% for very soluble gases Pulp and paper industry Chemical process industry Food industry Metals processing industry Particles: 0.5-5 in of water 50-100 gal/1,000 ft 3: 15-120 psig 1 ...
The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.