The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories is the main standard used by testing and calibration laboratories. In most countries, ISO/IEC 17025 is the standard for which most labs must hold accreditation in order to be deemed technically competent.
Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment. For example, the K3/K4 section would maintain Frequency counter, Oscilloscope, Synthesized Signal Generator and power sensor. While K1/K8 would maintain digital multimeter, high voltage probe and resistance standards. Lastly K5 ...
ASME Y14.5 is a complete definition of Geometric Dimensioning and Tolerancing. It contains 15 sections which cover symbols and datums as well as tolerances of form, orientation, position, profile and runout. [3] It is complemented by ASME Y14.5.1 - Mathematical Definition of Dimensioning and Tolerancing Principles.
reference (AAA): small tolerance (±0.05 μm) used to establish standards; calibration (AA): (tolerance +0.10 μm to −0.05 μm) used to calibrate inspection blocks and very high precision gauging; inspection (A): (tolerance +0.15 μm to −0.05 μm) used as toolroom standards for setting other gauging tools
BS 8888 is the British standard developed by the BSI Group for technical product documentation, geometric product specification, geometric tolerance specification and engineering drawings. [ 1 ] History
A calibration gas is a reference gas or gas mixture used as comparative standard in the calibration of analytical instruments, like gas analysers or gas detectors. Therefore, a calibration gas has to be of a precisely defined nature or composition, like zero gas or span gas , for example 500 ppm carbon monoxide in nitrogen.
Example of true position geometric control defined by basic dimensions and datum features. Geometric dimensioning and tolerancing (GD&T) is a system for defining and communicating engineering tolerances via a symbolic language on engineering drawings and computer-generated 3D models that describes a physical object's nominal geometry and the permissible variation thereof.