Search results
Results from the WOW.Com Content Network
≈ 5.1 4 × 10 −1 m/s 2: metre per second squared (SI unit) m/s 2: ≡ 1 m/s 2 = 1 m/s 2: mile per hour per second: mph/s ≡ 1 mi/(h⋅s) = 4.4704 × 10 −1 m/s 2: mile per minute per second: mpm/s ≡ 1 mi/(min⋅s) = 26.8224 m/s 2: mile per second squared: mps 2: ≡ 1 mi/s 2 = 1.609 344 × 10 3 m/s 2: standard gravity: g 0: ≡ 9.806 65 ...
The SI unit is cubic metres per second (m 3 /s). Another unit used is standard cubic centimetres per minute (SCCM). In US customary units and imperial units, volumetric flow rate is often expressed as cubic feet per second (ft 3 /s) or gallons per minute (either US or imperial definitions).
Until 1982, STP was defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of 101.325 kPa (1 atm). Since 1982, STP is defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of 100 kPa (1 bar). Conversions between each volume flow metric are calculated using the following formulas: Prior to 1982,
Mass flow rate is defined by the limit [3] [4] ˙ = =, i.e., the flow of mass through a surface per time .. The overdot on ˙ is Newton's notation for a time derivative.Since mass is a scalar quantity, the mass flow rate (the time derivative of mass) is also a scalar quantity.
The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture units. For example, 1000 FU is equivalent to 220 US gallons per minute (0.014 m 3 /s) while 2000 FU represents only 330 US gallons per minute (0.021 m 3 /s), about 1.5 times the flow rate.
In fluid dynamics, dynamic pressure (denoted by q or Q and sometimes called velocity pressure) is the quantity defined by: [1] = where (in SI units): q is the dynamic pressure in pascals (i.e., N/m 2, ρ (Greek letter rho) is the fluid mass density (e.g. in kg/m 3), and; u is the flow speed in m/s.
PO gpm = pump output in gpm (gallons per minute) 1 gallon = 0.0238095238 barrels; ID 2 = inside diameter of the wellbore or casing, squared; OD 2 = outside diameter of the drill pipe or tubing, squared; 1029.4 = A conversion factor constant used to calculate the volume between the outside of a tube within the inside of another tube, using barrels.
References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day).