To determine five-day biochemical oxygen demand (BOD 5), several dilutions of a sample are analyzed for dissolved oxygen before and after a five-day incubation period at 20 °C in the dark. In some cases, bacteria are used to provide a standardized community to uptake oxygen while consuming the organic matter in the sample; these bacteria are ...
The total protein concentration is exhibited by a color change of the sample solution in proportion to protein concentration, which can then be measured using colorimetric techniques. It is named for the biochemist Oliver H. Lowry who developed the reagent in the 1940s. His 1951 paper describing the technique is the most-highly cited paper ever ...
In analytical chemistry, a standard solution (titrant or titrator) is a solution containing an accurately known concentration.Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1]
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Quality control begins with sample collection and ends with the reporting of data. [4] AQC is achieved through laboratory control of analytical performance. Initial control of the complete system can be achieved through specification of laboratory services, instrumentation, glassware, reagents, solvents, and gases.
This is especially important for solid samples where there is a strong matrix influence. [5] In cases with complex or unknown matrices, the standard addition method can be used. [3] In this technique, the response of the sample is measured and recorded, for example, using an electrode selective for the analyte.
In LC, the concerns involving sample preparation can be minimal. In LC, both the stationary and mobile phase can affect the separation, whereas in GC only the stationary phase should be influential. This allows for the sample preparation to be minimal if one is willing to adjust the stationary phase or mobile phase before running the sample.
Chemical tests use reagents to indicate the presence of a specific chemical in an unknown solution. The reagents cause a unique reaction to occur based on the chemical it reacts with, allowing one to know what chemical is in the solution. An example is Heller's test where a test tube containing proteins has strong acids added to it.