In analytical chemistry, a standard solution (titrant or titrator) is a solution containing an accurately known concentration.Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1]
Other interference may come from the buffer used when preparing the protein sample. A high concentration of buffer will cause an overestimated protein concentration due to depletion of free protons from the solution by conjugate base from the buffer. This will not be a problem if a low concentration of protein (subsequently the buffer) is used. [6]
The elementary reaction responsible for water quantification in the Karl Fischer titration is oxidation of sulfur dioxide (SO 2) with iodine: . H 2 O + SO 2 + I 2 → SO 3 + 2 HI. This elementary reaction consumes exactly one molar equivalent of water vs. iodine.
This reaction is rapid and stoichiometric, with the addition of one mole of thiol releasing one mole of TNB. The TNB 2− is quantified in a spectrophotometer by measuring the absorbance of visible light at 412 nm, using an extinction coefficient of 14,150 M −1 cm −1 for dilute buffer solutions, [4] [5] and a coefficient of 13,700 M −1 cm −1 for high salt concentrations, such as 6 M ...
FIA is an automated method of chemical analysis in which a sample is injected into a flowing carrier solution that mixes with reagents before reaching a detector. Over past 30 years, FIA techniques developed into a wide array of applications using spectrophotometry , fluorescence spectroscopy , atomic absorption spectroscopy , mass spectrometry ...
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The method combines the reactions of copper ions with the peptide bonds under alkaline conditions (the Biuret test) with the oxidation of aromatic protein residues. The Lowry method is based on the reaction of Cu +, produced by the oxidation of peptide bonds, with Folin–Ciocalteu reagent (a mixture of phosphotungstic acid and phosphomolybdic acid in the Folin–Ciocalteu reaction).
AQC is achieved through laboratory control of analytical performance. Initial control of the complete system can be achieved through specification of laboratory services, instrumentation, glassware, reagents, solvents, and gases. However, evaluation of daily performance must be documented to ensure continual production of valid data.