Search results
Results from the WOW.Com Content Network
FIA is an automated method of chemical analysis in which a sample is injected into a flowing carrier solution that mixes with reagents before reaching a detector. Over past 30 years, FIA techniques developed into a wide array of applications using spectrophotometry , fluorescence spectroscopy , atomic absorption spectroscopy , mass spectrometry ...
calculations and statistics: Protocols for methods that produce numerical results generally include detailed formulas for calculation of results. A formula may also be included for preparation of reagents and other solutions required for the work. Methods of statistical analysis may be included to guide interpretation of the data.
Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.
Other interference may come from the buffer used when preparing the protein sample. A high concentration of buffer will cause an overestimated protein concentration due to depletion of free protons from the solution by conjugate base from the buffer. This will not be a problem if a low concentration of protein (subsequently the buffer) is used. [6]
The elementary reaction responsible for water quantification in the Karl Fischer titration is oxidation of sulfur dioxide (SO 2) with iodine: . H 2 O + SO 2 + I 2 → SO 3 + 2 HI. This elementary reaction consumes exactly one molar equivalent of water vs. iodine.
Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte (the ion being analyzed) based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative ...
A solution containing antibody is added to a heated medium such as agar or agarose dissolved in buffered normal saline.The molten medium is then poured onto a microscope slide or into an open container, such as a Petri dish, and allowed to cool and form a gel.
Here, a primary standard is typically a reagent which can be weighed easily, and which is so pure that its weight is truly representative of the number of moles of substance contained. Features of a primary standard include: High purity; Stability (low reactivity) Low hygroscopicity (to minimize weight changes due to humidity)