enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. TAE buffer - Wikipedia

    en.wikipedia.org/wiki/TAE_buffer

    TAE buffer is commonly prepared as a 50× stock solution for laboratory use. A 50× stock solution can be prepared by dissolving 242 g Tris base in water, adding 57.1 ml glacial acetic acid, and 100 ml of 500 mM EDTA (pH 8.0) solution, and bringing the final volume up to 1 litre.

  3. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    Other interference may come from the buffer used when preparing the protein sample. A high concentration of buffer will cause an overestimated protein concentration due to depletion of free protons from the solution by conjugate base from the buffer. This will not be a problem if a low concentration of protein (subsequently the buffer) is used. [6]

  4. Flow injection analysis - Wikipedia

    en.wikipedia.org/wiki/Flow_injection_analysis

    FIA is an automated method of chemical analysis in which a sample is injected into a flowing carrier solution that mixes with reagents before reaching a detector. Over past 30 years, FIA techniques developed into a wide array of applications using spectrophotometry , fluorescence spectroscopy , atomic absorption spectroscopy , mass spectrometry ...

  5. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    The elementary reaction responsible for water quantification in the Karl Fischer titration is oxidation of sulfur dioxide (SO 2) with iodine: . H 2 O + SO 2 + I 2 → SO 3 + 2 HI. This elementary reaction consumes exactly one molar equivalent of water vs. iodine.

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.

  8. Spartan (chemistry software) - Wikipedia

    en.wikipedia.org/wiki/Spartan_(chemistry_software)

    Spartan is a molecular modelling and computational chemistry application from Wavefunction. [2] It contains code for molecular mechanics, semi-empirical methods, ab initio models, [3] density functional models, [4] post-Hartree–Fock models, [5] thermochemical recipes including G3(MP2) [6] and T1.

  9. Lawesson's reagent - Wikipedia

    en.wikipedia.org/wiki/Lawesson's_reagent

    Lawesson's reagent (LR) is a chemical compound used in organic synthesis as a thiation agent. Lawesson's reagent was first made popular by Sven-Olov Lawesson , who did not, however, invent it. Lawesson's reagent was first made in 1956 during a systematic study of the reactions of arenes with P 4 S 10 .