A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A related term sealing current (aka wetting current or fritting current) is widely used in the telecommunication industry describing a small constant DC current (typically 1-20 mA) in copper wire loops in order to avoid contact oxidation of contacts and splices.
An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).
Residual-current device (RCD), also residual current circuit breaker (RCCB) A circuit breaker triggered by unequal currents in line and neutral wires (i.e., electrical power is passing to earth). Mandatory for most circuits as of 17th Edition regulations. Residual current circuit breaker with overcurrent protection (RCBO)
The Code gives rules for calculating circuit loading and maximum ampacity. Ground-fault circuit interrupter (GFCI) protection is required on receptacles in wet locations and locations where there exists an easy path for fault current to travel to earth. This includes all receptacles intended to service kitchen counter surfaces, crawl spaces at ...
Miniature circuit breaker (MCB)—rated current up to 125 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category. Molded Case Circuit Breaker (MCCB)—rated current up to 1,600 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in higher-rated ...
When current flows from a line conductor to an earth wire, as is the case when a line conductor makes contact with an earthed surface in a Class I appliance, an automatic disconnection of supply (ADS) device such as a circuit breaker or a residual-current device (RCD) will automatically open the circuit to clear the fault. [7]
Retrieved from "https://en.wikipedia.org/w/index.php?title=Residual-current_circuit_breaker&oldid=41774014"