enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The test is typically performed over a range of test voltages from 0.5 Uo to 2 Uo depending on the standard/guide that is being followed. Apply VLF in order to detect and measure partial discharge . In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high ...

  3. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 62057-1 Electrical energy meters – Test equipment, techniques and procedures – Part 1: Stationary meter test units (MTUs) IEC 62057-3 Electrical energy meters – Test equipment, techniques and procedures – Part 3: Automatic meter testing system (AMTS) IEC 62058 Electricity metering equipment (AC) – Acceptance inspection

  4. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    A great deal of THWN wire is actually dual-rated, and meets THHN the specification as well, so may be used in wet environments up to 75°C or dry environments up to 90°C. An extended specification, THWN-2 permits use in wet locations and conductor temperatures up to 90°C simultaneously. [18]

  6. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    The standard takes account of the technical substance of agreements reached in CENELEC. [2] BS 7671 is also used as a national standard by Mauritius, St Lucia, Saint Vincent and the Grenadines, Sierra Leone, Singapore, Sri Lanka, Trinidad and Tobago, Uganda, Cyprus, and several other countries, which base their wiring regulations on it.

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association . [ 1 ]

  8. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    An electrical code is a term for a set of regulations for the design and installation of electrical wiring in a building. The intention of such regulations is to provide standards to ensure electrical wiring systems are safe for people and property, protecting them from electrical shock and fire hazards.

  9. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    In electrical engineering, electrical safety testing is essential to make sure electrical products and installations are safe. To meet this goal, governments and various technical bodies have developed electrical safety standards. All countries have their own electrical safety standards that must be complied with.