Search results
Results from the WOW.Com Content Network
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon-carbon multiple bonds, there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next ...
The R- numbering system was developed by DuPont (which owned the Freon trademark), and systematically identifies the molecular structure of refrigerants made with a single halogenated hydrocarbon. ASHRAE has since set guidelines for the numbering system as follows: [85] R-X 1 X 2 X 3 X 4. X 1 = Number of unsaturated carbon-carbon bonds (omit if ...
HFO-1234yf was developed by a team at DuPont, led by Barbara Haviland Minor, jointly with researchers at Honeywell. [8] [9] Their goal was to meet European directive 2006/40/EC, which went into effect in 2011 and required that all new car platforms for sale in Europe use a refrigerant in its AC system with a global warming potential (GWP) less than 150 times more potent than carbon dioxide.
R-410A was invented and patented by Allied Signal (now Honeywell) in 1991. [5] Other producers around the world have been licensed to manufacture and sell R-410A. [6] R-410A was successfully commercialized in the air conditioning segment by a combined effort of Carrier Corporation, Emerson Climate Technologies, Inc., Copeland Scroll Compressors (a division of Emerson Electric Company), and ...
The cis isomer's ASHRAE number is R-1112c, and its CAS number is 311-81-9. Its melting point is −119.6 °C (−183.3 °F). [5] The trans isomer's ASHRAE number is R-1112t, and its CAS number is 381-71-5. Its melting point is −93.3 °C (−135.9 °F). [5] The diastereomers are commercially only available as a mixtures of varying proportions.
Whereas for azeotropic mixtures they are assigned a number in the 500 series. According to ASHRAE, refrigerants names start with 'R' followed by a series of numbers—400 series if it is zeotropic or 500 if it is azeotropic—followed by uppercase letters that denote the composition. [18]
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
Because of its reduced global warming potential (GWP), R-454B is intended to be an alternative to refrigerant R-410A in new equipment. [2] [3] [4] R-454B has a GWP of 466, which is 78 percent lower than R-410A's GWP of 2088. [2] R-454B is non-toxic and mildly flammable, with an ASHRAE safety classification of A2L. In the United States, it is ...