Search results
Results from the WOW.Com Content Network
AWG is colloquially referred to as gauge and the zeros in thick wire sizes are referred to as aught / ˈ ɔː t /. Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are ...
A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.
No. 7/0, the largest size, is 0.50 inches (500 mils or 12.7 mm) in diameter (250 000 circular mils in cross-sectional area), and the smallest, No. 50, is 0.001 inches (1 mil or 25.4 μm) in diameter (1 circular mil [cross-sectional area] or 0.7854 millionths of a square inch).
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid, by CMG Lee. In the SVG file, hover over an item to highlight it. Width: 100%: Height: 100%
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
0.7854 square mils (1 square mil is about 1.273 circular mils) 7.854 × 10 −7 square inches (1 square inch is about 1.273 million circular mils) 5.067 × 10 −10 square metres; 5.067 × 10 −4 square millimetres; 506.7 μm 2; 1000 circular mils = 1 MCM or 1 kcmil, and is (approximately) equal to: 0.5067 mm 2, so 2 kcmil ≈ 1 mm 2 (a 1.3% ...
The American wire gauge scale is based on this. This can be done on a small scale with a draw plate, or on a large commercial scale using automated machinery. [1] [2] The process of wire drawing changes material properties due to cold working. The area reduction in small wires is generally 15–25% and in larger wires is 20–45%. [1]
American wire gauge, a common measure of nonferrous wire diameter, especially electrical; Birmingham gauge, a measure of ferrous wire and hypodermic needle diameter; Jewelry wire gauge, the size of wire used in jewelry making; Sheet metal gauge, thickness of metal in sheet form; Film gauge, a physical property of film stock which defines its size