Results from the WOW.Com Content Network
The use of highly compressed straw bales as insulation, though uncommon, is gaining popularity in experimental building projects for the high R-value and low cost of a thick wall made of straw. "Research by Joe McCabe at the Univ. of Arizona found R-value for both wheat and rice bales was about R-2.4 (RSI-0.42) per inch with the grain, and R-3 ...
This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
The reported R-value ranges from 17–55 (in American units) or 3–9.6 (in SI) depending on the study, differing wall designs could be responsible for wide range in R-value. [ 33 ] [ 34 ] given that the bales are over a foot thick, the R-value per inch is lower than most other commercial insulation types including batts (3–4) and foamboard (~5).
Loose cellulose, fibreglass (both blown and in batts), and rock wool (both blown and in batts) all possess an R-value of roughly R-2.5 to R-4 per inch. Straw bales perform at about R-2.38 to 2.68 per inch, depending on orientation of the bales. [42] However, typical straw bale houses have very thick walls and thus are well insulated. Snow is ...
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...
The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...