Wet cooling towers or open-circuit Cooling Tower or evaporative cooling towers operate on the principle of evaporative cooling. The working coolant (usually water) is the evaporated fluid, and is exposed to the elements.
Cooling towers are structures for cooling water or other heat transfer media to near-ambient wet-bulb temperature. Wet cooling towers operate on the evaporative cooling principle, but are optimized to cool the water rather than the air. Cooling towers can often be found on large buildings or on industrial sites.
The cooling towers of a large chilled water system. As part of a chilled water system, the condenser water absorbs heat from the refrigerant in the condenser barrel of the water chiller and is then sent via return lines to a cooling tower, which is a heat exchange device used to transfer waste heat to the atmosphere.
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...
The evaporative cooling within a windtower causes the air in the tower to sink, driving circulation. This is called passive downdraught evaporative cooling (PDEC). It may also be generated using spray nozzles (which have a tendency to get blocked if the water is hard) or cold-water cooling coils (like hydronic underfloor heating in reverse). [5]
Absorption cooling was invented by the French scientist Ferdinand Carré in 1858. [1] The original design used water and sulphuric acid. In 1922, two students at the Royal Institute of Technology in Stockholm, Sweden, Baltzar von Platen and Carl Munters, enhanced the principle with a three-fluid configuration. This "Platen-Munters" design can ...
The cooling tower water can be directly linked into the flow through the chilled water circuit. If the cooling tower is open then a strainer is required to eliminate any debris that could accumulate within the tower. The cost savings are associated with the limited use of the water chiller energy. There is an increased risk of corrosion using ...
The equipment used can consist of machines used to remove heat such as a chiller or a cooling tower and equipment for adding heat to the building's water such as a boiler or a commercial water heater. Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units ...