enow.com Web Search

  1. Ads

    related to: what does pka equal ph meter

Search results

  1. Results from the WOW.Com Content Network
  2. Acid dissociation constant - Wikipedia

    en.wikipedia.org/wiki/Acid_dissociation_constant

    The solution is then titrated with a strong base until all the protons have been removed. At each point in the titration pH is measured using a glass electrode and a pH meter. The equilibrium constants are found by fitting calculated pH values to the observed values, using the method of least squares. [59]

  3. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    To calibrate the electrode, it is first immersed in a standard solution, and the reading on a pH meter is adjusted to be equal to the standard buffer's value. The reading from a second standard buffer solution is then adjusted using the "slope" control to be equal to the pH for that solution. Further details, are given in the IUPAC ...

  4. Acid strength - Wikipedia

    en.wikipedia.org/wiki/Acid_strength

    When the acidic medium in question is a dilute aqueous solution, the is approximately equal to the pH value, which is a negative logarithm of the concentration of aqueous + in solution. The pH of a simple solution of an acid in water is determined by both K a {\displaystyle K_{{\ce {a}}}} and the acid concentration.

  5. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    A pH meter is a scientific instrument that ... The pH meter has one calibration control to set the meter reading equal to the value of the first standard buffer and a ...

  6. Buffer solution - Wikipedia

    en.wikipedia.org/wiki/Buffer_solution

    A buffer solution is a solution where the pH does not change significantly on dilution or if an acid or base is added at constant temperature. [1] Its pH changes very little when a small amount of strong acid or base is added to it. Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical ...

  7. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The pH meter is usually calibrated with buffer solutions at known pH values before starting the titration. The ionic strength can be kept constant by judicious choice of acid and base. For instance, HCl titrated with NaOH of approximately the same concentration will replace H + with an ion (Na + ) of the same charge at the same concentration ...

  8. Weak base - Wikipedia

    en.wikipedia.org/wiki/Weak_base

    With pOH obtained from the pOH formula given above, the pH of the base can then be calculated from =, where pK w = 14.00. A weak base persists in chemical equilibrium in much the same way as a weak acid does, with a base dissociation constant (K b) indicating the strength of the base. For example, when ammonia is put in water, the following ...

  9. Potassium hydrogen phthalate - Wikipedia

    en.wikipedia.org/wiki/Potassium_hydrogen_phthalate

    The buffering region is dependent upon the pKa, and is typically +/- 1.0 pH units of the pKa. The pKa of KHP is 5.4, so its pH buffering range would be 4.4 to 6.4; however, due to the presence of the second acidic group that bears the potassium ion, the first pKa also contributes to the buffering range well below pH 4.0, which is why KHP is a ...

  1. Ads

    related to: what does pka equal ph meter