enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. AC adapter - Wikipedia

    en.wikipedia.org/wiki/AC_adapter

    A linear circuit must be designed for a specific, narrow range of input voltages (e.g., 220–240 VAC) and must use a transformer appropriate for the frequency (usually 50 or 60 Hz), but a switched-mode supply can work efficiently over a very wide range of voltages and frequencies; a single 100–240 VAC unit will handle almost any mains supply ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    On the three secondary terminals, the center tap is grounded with a short strap to the transformer case. A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage ...

  4. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    For example, in North America, a unique split-phase system is used to supply to most premises that works by center tapping a 240 volt transformer. This system is able to concurrently provide 240 volts and 120 volts. Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes).

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  6. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    All NEMA 6 devices are three-wire grounding devices (hot-hot-ground) used for 208 and 240 V circuits and rated for 250 V maximum, with the 6-15, 6-20 and 6-30 being grounding versions of the 2-15, 2-20 and 2-30, respectively. The 6-15 resembles the 5-15, but with collinear horizontal pins, spaced 23 ⁄ 32 in (18.3 mm) center-to-center. The 20 ...

  7. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  8. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    Minimum wire size for hand-held or portable equipment is usually restricted by the mechanical strength of the conductors. Many areas, such as the US, which use (nominally) 120 V, make use of three-wire, split-phase 240 V systems to supply large appliances. In this system a 240 V supply has a centre-tapped neutral to give two 120 V supplies ...

  9. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...