Search results
Results from the WOW.Com Content Network
To express the efficiency of a generator or power plant as a percentage, invert the value if dimensionless notation or same unit are used. For example: A heat rate value of 5 gives an efficiency factor of 20%. A heat rate value of 2 kWh/kWh gives an efficiency factor of 50%. A heat rate value of 4 MJ/MJ gives an efficiency factor of 25%.
When there is enough flow, power output is limited by plant generating capacity. The maximum power-output curves were calculated based on the average flow rate at the dam site, assuming the water level is 175 m and the plant gross efficiency is 90.15%. The actual power output in 2008 was obtained based on the monthly electricity sent to the grid.
Variable speed operation further optimizes the round trip efficiency in pumped hydro storage plants. [ 5 ] [ 6 ] In micro-PSH applications, a group of pumps and Pump As Turbine (PAT) could be implemented respectively for pumping and generating phases. [ 7 ]
The six-year project would begin in 2013 and extend the plant's life by at least forty years and upgrade the generating capacity from 1,872 megawatts to 2,172 megawatts. [10] Plans for the upgrade include replacing all six of the plant's turbines, which would increase the plant's total generating capacity by 15 percent, and efficiency by 5 percent.
For example, a low-head hydro power plant with hydrostatic head of few meters to few tens of meters can be classified either as an SHP or an LHP. [30] The other distinction between SHP and LHP is the degree of the water flow regulation: a typical SHP primarily uses the natural water discharge with very little regulation in comparison to an LHP.
The energy efficiency of a fuel cell is generally between 40 and 60%; however, if waste heat is captured in a cogeneration scheme, efficiencies of up to 85% can be obtained. [24] World average fossil fuel electricity generation power plant as of 2008 [25] Chemical to electrical Gross output 39%, Net output 33% Electricity storage: Lithium-ion ...
The plant was built to store excess energy from the Vermont Yankee Nuclear Power Plant, but that plant was shut down in 2014.The pumped-storage plant is still in operation, but according to activist site Connecticut River Defenders [5] it is no longer needed, as it is only storing energy from fossil-fuel plants, and is harming the Connecticut River ecosystem, killing all river life that passes ...
The pumped-storage hydroelectric plant was constructed from 1960–1962 and was designed to help meet daytime peak electric power demand. [8] It began operation in 1963. Electrical generators are turned by water flowing from a reservoir on top of Proffit Mountain into a lower reservoir on the East Fork of the Black River. At night, excess ...