enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    For a wind farm, the capacity factor is determined by the availability of wind, the swept area of the turbine and the size of the generator. Transmission line capacity and electricity demand also affect the capacity factor. Typical capacity factors of current wind farms are between 25 and 45%. [12]

  3. Levelized cost of electricity - Wikipedia

    en.wikipedia.org/wiki/Levelized_cost_of_electricity

    The assumption of the capacity factor has a significant impact on the calculation of LCOE as it determines the actual amount of energy produced by specific installed power. Formulas that output cost per unit of energy ($/MWh) already account for the capacity factor, while formulas that output cost per unit of power ($/MW) do not. [12]

  4. Cost of electricity by source - Wikipedia

    en.wikipedia.org/wiki/Cost_of_electricity_by_source

    In 2012, it produced 268 GWh of electricity, achieving a capacity factor of just over 50%. [31] If the overnight cost is calculated for the nameplate capacity, it works out to €4167 per kW whereas if one takes into account the capacity factor, the figure needs to be roughly doubled.

  5. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  6. Capacity credit - Wikipedia

    en.wikipedia.org/wiki/Capacity_credit

    The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added).

  7. Chemical plant cost indexes - Wikipedia

    en.wikipedia.org/wiki/Chemical_plant_cost_indexes

    The selection of the proper index to use depends on the industry in which it is applied. For example, while CE, M&S or IC Index are typically employed for chemical process industries, the ENR (Engineering News-Record) construction index is used for general industrial construction and takes in account the prices for fixed amounts of structural steel, cement, lumber and labor.

  8. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power flow calculated from AC voltage and current entering a load having a zero power factor (ϕ = 90°, cos(ϕ) = 0).The blue line shows the instantaneous power entering the load: all of the energy received during the first (or third) quarter cycle is returned to the grid during the second (or fourth) quarter cycle, resulting in an average power flow (light blue line) of zero.

  9. Minimum-cost flow problem - Wikipedia

    en.wikipedia.org/wiki/Minimum-cost_flow_problem

    The minimum-cost flow problem (MCFP) is an optimization and decision problem to find the cheapest possible way of sending a certain amount of flow through a flow network.A typical application of this problem involves finding the best delivery route from a factory to a warehouse where the road network has some capacity and cost associated.