An ABG test measures the blood gas tension values of the arterial partial pressure of oxygen (PaO2), and the arterial partial pressure of carbon dioxide (PaCO2), and the blood's pH. In addition, the arterial oxygen saturation (SaO2) can be determined. Such information is vital when caring for patients with critical illnesses or respiratory disease.
Normal arterial blood oxygen saturation levels in humans are 96–100 percent. [1] If the level is below 90 percent, it is considered low and called hypoxemia . [ 2 ] Arterial blood oxygen levels below 80 percent may compromise organ function, such as the brain and heart, and should be promptly addressed.
Oxygen may also be given to the patient to see if that increases oxygen levels in the tissue. The test takes about 45 minutes. Results are reported either as the absolute values of the tissue in question (in mmHg ) or as a ratio of the tissue in question to the control tissue.
Pulse oximetry is a noninvasive method for monitoring blood oxygen saturation. Peripheral oxygen saturation (SpO 2) readings are typically within 2% accuracy (within 4% accuracy in 95% of cases) of the more accurate (and invasive) reading of arterial oxygen saturation (SaO 2) from arterial blood gas analysis.
2 indicates that the patient's current minute ventilation (whether high or normal) is not enough to allow adequate oxygen diffusion into the blood. Therefore, the A–a gradient essentially demonstrates a high respiratory effort (low arterial PaCO 2) relative to the achieved level of oxygenation (arterial PaO 2). A high A–a gradient could ...
Finger tip carboxyhemoglobin saturation monitor.. A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb).
Dissolved oxygen levels required by various species in the Chesapeake Bay (US). In aquatic environments, oxygen saturation is a ratio of the concentration of "dissolved oxygen" (DO, O 2), to the maximum amount of oxygen that will dissolve in that water body, at the temperature and pressure which constitute stable equilibrium conditions.
Arterial blood oxygen tension (normal) P a O 2 – Partial pressure of oxygen at sea level (160 mmHg (21.3 kPa) in the atmosphere, 21% of the standard atmospheric pressure of 760 mmHg (101 kPa)) in arterial blood is between 75 and 100 mmHg (10.0 and 13.3 kPa).