A condenser (right) and its respective diaphragm (left) A condenser is an optical lens that renders a divergent light beam from a point light source into a parallel or converging beam to illuminate an object to be imaged. Condensers are an essential part of any imaging device, such as microscopes, enlargers, slide projectors, and telescopes.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.
A requirement for this method is that the incoming beam of light is as parallel as possible. This requires the closing down of the sub-stage condenser iris. Closing the sub-stage condenser iris decreases the resolution of the particle and increases the depth of field over which other objects may interfere with the effect seen.
[[Category:Chart, diagram and graph formatting and function templates]] to the <includeonly> section at the bottom of that page. Otherwise, add <noinclude>[[Category:Chart, diagram and graph formatting and function templates]]</noinclude> to the end of the template code, making sure it starts on the same line as the code's last character.
A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.
A broadband “white light” source is used to illuminate the test and reference surfaces. A condenser lens collimates the light from the broadband light source. A beam splitter separates the light into reference and measurement beams. The reference beam is reflected by the reference mirror, while the measurement beam is reflected or scattered ...
The phase telescope/Bertrand lens is inserted into the microscope in place of an eyepiece to move the intermediate image plane to a point where it can be observed. Phase telescopes are primarily used for aligning the optical components required for Köhler illumination and phase contrast microscopy. For Köhler illumination the light source and ...