enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    In electrical engineering, current sensing is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude, accuracy, bandwidth, robustness, cost, isolation or size. The current ...

  3. Continuity test - Wikipedia

    en.wikipedia.org/wiki/Continuity_test

    In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise-producing component such as a piezoelectric speaker) across the chosen path.

  4. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...

  5. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    This no-load current is very small and because the copper loss in the primary is proportional to the square of this current, it is negligible. There is no copper loss in the secondary because there is no secondary current. [1] The secondary side of the transformer is left open, so there is no load on the secondary side.

  6. Electromagnetic testing - Wikipedia

    en.wikipedia.org/wiki/Electromagnetic_testing

    Eddy-current testing (ECT) is used to detect near-surface cracks and corrosion in metallic objects such as tubes and aircraft fuselage and structures. ECT is more commonly applied to nonferromagnetic materials, since in ferromagnetic materials the depth of penetration is relatively small.

  7. Electric current - Wikipedia

    en.wikipedia.org/wiki/Electric_current

    Electric current can be directly measured with a galvanometer, but this method involves breaking the electrical circuit, which is sometimes inconvenient. Current can also be measured without breaking the circuit by detecting the magnetic field associated with the current. Devices, at the circuit level, use various techniques to measure current:

  8. Eddy-current testing - Wikipedia

    en.wikipedia.org/wiki/Eddy-current_testing

    Tubing inspection is generally limited to non-ferromagnetic tubing and is known as conventional eddy current testing. Conventional ECT is used for inspecting steam generator tubing in nuclear plants and heat exchangers tubing in power and petrochemical industries. The technique is very sensitive to detect and size pits.

  9. AOL Mail

    mail.aol.com/?offerId=netscapeconnect-en-us

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!