enow.com Web Search

  1. Ads

    related to: condensate removal pump not working

Search results

  1. Results from the WOW.Com Content Network
  2. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    Condensate pumps are used in hydronic systems that cannot discharge excess condensate water via a gravity feed. Condensate pumps are usually electrically powered centrifugal pumps . They are used to remove condensate water from HVAC systems that cannot be accomplished via gravity, and therefore the water must be pumped up.

  3. Steam trap - Wikipedia

    en.wikipedia.org/wiki/Steam_trap

    Three views of a c.1885 steam trap. The general appearance of this arrangement is as in Fig. 1 or Fig. 3, the center view, Fig. 2, shows the cardinal feature of this trap, that it contains a collector for silt, sand, or sediment which is not, as in most other traps of the time, carried out through the valve with the efflux of water.

  4. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...

  5. Steam–electric power station - Wikipedia

    en.wikipedia.org/wiki/Steam–electric_power_station

    The condensate pump then pumps the condensate water through a feedwater heater, which raises the temperature of the water by using extraction steam from various stages of the turbine. [5] [6] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system. [9]

  6. Cold trap - Wikipedia

    en.wikipedia.org/wiki/Cold_trap

    [3] [4] Reversing this, connecting the down tube to the source of vacuum, places the inlet of the vacuum directly above the condensate, increasing the chances of vapour phase condensate moving up the (uncooled) down tube (towards the pump) or, should the trap begin to fill to an appreciable volume, liquid phase condensate being pulled into the ...

  7. Surface condenser - Wikipedia

    en.wikipedia.org/wiki/Surface_condenser

    At the bottom of the shell, where the condensate collects, an outlet is installed. In some designs, a sump (often referred to as the hotwell) is provided. Condensate is pumped from the outlet or the hotwell for reuse as boiler feedwater. For most water-cooled surface condensers, the shell is under [partial] vacuum during normal operating ...

  8. 15 Things That Will Always Fail a Home Inspection (and ... - AOL

    www.aol.com/15-things-always-fail-home-160000027...

    Once you understand why a home might fail inspection, you can better formulate a repair plan. Here are 15 common things that may come up and what you can do to address the issues.

  9. Condensing steam locomotive - Wikipedia

    en.wikipedia.org/wiki/Condensing_steam_locomotive

    Ordinary injectors will not work with hot water [5] (until hot-water injectors were developed) so condensing locomotives were usually fitted with axle-driven boiler feedwater pumps. When not working in tunnels, the steam was directed to the blast pipe and up the chimney in the usual way.

  1. Ads

    related to: condensate removal pump not working