A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug , AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding -type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
In transmission line faults, roughly 5% - 10% are asymmetric line-to-line faults. [2] line-to-ground fault - a short circuit between one line and ground, very often caused by physical contact, for example due to lightning or other storm damage. In transmission line faults, roughly 65% - 70% are asymmetric line-to-ground faults. [2]
Incorrectly configured or old model reclosers have been implicated in the starting or spread of wildfires. Research into the Australian 2009 Black Saturday Bushfires indicated that reclosers operating as single shot circuit breakers with Sensitive Ground Fault protection configured at 500mA would reduce fire start risk by 80%.
Conversely, when the generator backfeed circuit breaker is turned on, the main circuit breaker is blocked and will remain off. The generator backfeed circuit breaker is connected to a generator inlet installed (preferably) on the outside of the structure. A short cord connects the generator to the house inlet, usually through a twistlock plug ...
The main attraction of a TN network is the low impedance earth path allows easy automatic disconnection (ADS) on a high current circuit in the case of a line-to-PE fault as the same breaker or fuse will operate for either L-N or L-PE faults, and an RCD is not needed to detect earth faults.
A ground conductor only carries significant current if there is a circuit fault that would otherwise energize exposed conductive parts and present a shock hazard. In that case, circuit protection devices may detect a fault to a grounded metal enclosure and automatically de-energize the circuit, or may provide a warning of a ground fault.
The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.