Search results
Results from the WOW.Com Content Network
The Pixar Photoscience Division, a division of Pixar Animation Studios, was founded in 1979 at Lucasfilm for the express purpose of designing and building a laser recorder/scanner system to input and output film to a computer for compositing and color correction of special effects. In the early years of Pixar's history, the team was responsible ...
A gamma camera (γ-camera), also called a scintillation camera or Anger camera, is a device used to image gamma radiation emitting radioisotopes, a technique known as scintigraphy. The applications of scintigraphy include early drug development and nuclear medical imaging to view and analyse images of the human body or the distribution of ...
Scintigraphy (from Latin scintilla, "spark"), also known as a gamma scan, is a diagnostic test in nuclear medicine, where radioisotopes attached to drugs that travel to a specific organ or tissue (radiopharmaceuticals) are taken internally and the emitted gamma radiation is captured by gamma cameras, which are external detectors that form two-dimensional images [1] in a process similar to the ...
The telerecording film chain can be arranged to produce a direct negative-image film recording, a direct positive-image film recording, or a positive print can be made from the negative. In the first two cases we have the following four units in which local gamma or effective image contrast may be adjusted: The recording channel amplifier.
Making a radiograph. Industrial radiography is a modality of non-destructive testing that uses ionizing radiation to inspect materials and components with the objective of locating and quantifying defects and degradation in material properties that would lead to the failure of engineering structures.
The slope of its linear section is called the gamma of the film. When a photographic film is exposed to light, the result of the exposure can be represented on a graph showing log of exposure on the horizontal axis, and density, or negative log of transmittance, on the vertical axis.
Gamma-ray emission tomography ("Tomographic Gamma Scanning") Gamma ray: TGS or ECT Gamma-ray transmission tomography: Gamma ray: TCT Hydraulic tomography: fluid flow: HT 2000 Infrared microtomographic imaging [10] Mid-infrared: 2013 Laser Ablation Tomography: Laser ablation & fluorescent microscopy: LAT 2013 Magnetic induction tomography ...
Then, gamma cameras capture and form two-dimensional [12] images from the radiation emitted by the radiopharmaceuticals. SPECT is a 3D tomographic technique that uses gamma camera data from many projections and can be reconstructed in different planes. A dual detector head gamma camera combined with a CT scanner, which provides localization of ...