An artificial cardiac pacemaker, commonly referred to as simply a pacemaker, is an implanted medical device that generates electrical pulses delivered by electrodes to one or more of the chambers of the heart. Each pulse causes the targeted chamber (s) to contract and pump blood, [3] thus regulating the function of the electrical conduction ...
Cardiology. Pacemaker syndrome is a condition that represents the clinical consequences of suboptimal atrioventricular (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after pacemaker implantation. [1][2] It is an iatrogenic disease—an adverse effect resulting from medical treatment—that is often underdiagnosed. [1][3] In ...
The cardiac pacemaker is the heart 's natural rhythm generator. It employs pacemaker cells that produce electrical impulses, known as cardiac action potentials, which control the rate of contraction of the cardiac muscle, that is, the heart rate. In most humans, these cells are concentrated in the sinoatrial (SA) node, the primary pacemaker ...
Palpitations. An ectopic pacemaker, also known as ectopic focus or ectopic foci, is an excitable group of cells that causes a premature heart beat outside the normally functioning SA node of the heart. It is thus a cardiac pacemaker that is ectopic, producing an ectopic beat. Acute occurrence is usually non-life-threatening, but chronic ...
An implantable cardioverter-defibrillator (ICD) or automated implantable cardioverter defibrillator (AICD) is a device implantable inside the body, able to perform defibrillation, and depending on the type, cardioversion and pacing of the heart. The ICD is the first-line treatment and prophylactic therapy for patients at risk for sudden cardiac ...
Cardiac conduction system. The cardiac conduction system (CCS, also called the electrical conduction system of the heart) [1] transmits the signals generated by the sinoatrial node – the heart 's pacemaker, to cause the heart muscle to contract, and pump blood through the body's circulatory system. The pacemaking signal travels through the ...
Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles. [citation needed]
Heart block. Heart block (HB) [1] is a disorder in the heart 's rhythm due to a fault in the natural pacemaker. [2] This is caused by an obstruction – a block – in the electrical conduction system of the heart. Sometimes a disorder can be inherited. Despite the severe-sounding name, heart block may cause no symptoms at all in some cases, or ...