Standard cubic feet per minute (SCFM) is the molar flow rate of a gas expressed as a volumetric flow at a "standardized" temperature and pressure thus representing a fixed number of moles of gas regardless of composition and actual flow conditions.
The standard liter per minute (SLM or SLPM) is a unit of (molar or) mass flow rate of a gas at standard conditions for temperature and pressure (STP), which is most commonly practiced in the United States, whereas European practice revolves around the normal litre per minute (NLPM). [1]
A gas network is in the steady state when the values of gas flow characteristics are independent of time and system described by the set of nonlinear equations. The goal of simple simulation of a gas network is usually that of computing the values of nodes' pressures, loads and the values of flows in the individual pipes.
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
One example of standard conditions for the calculation of SCCM is = 0 °C (273.15 K) [1] and = 1.01 bar (14.72 psia) and a unity compressibility factor = 1 (i.e., an ideal gas is used for the definition of SCCM). [2] This example is for the semi-conductor-manufacturing industry.
Originally the gas flow computer was a mechanical (1920s technology) or later a pneumatic or hydraulic computing module (1940s technology used to the early 1990s but still available from a number of suppliers), subsequently superseded in most applications by an electronic module, as the primary elements switched from transmitting the measured variables from pneumatic or hydraulic pressure ...
The volume of gas flow provided by a gas meter is just that, a reading of volume. Gas volume does not take into account the quality of the gas or the amount of heat available when burned. Utility customers are billed according to the heat available in the gas. The quality of the gas is measured and adjusted for in each billing cycle.