enow.com Web Search

  1. Ads

    related to: 3 phase electrical systems

Search results

  1. Results from the WOW.Com Content Network
  2. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Electrical engineers try to design the three-phase power system for any one location so that the power drawn from each of three phases is the same, as far as possible at that site. [25] Electrical engineers also try to arrange the distribution network so the loads are balanced as much as possible, since the same principles that apply to ...

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The plotted line represents the variation of instantaneous voltage (or current) with respect to time. This cycle repeats with a frequency that depends on the power system. In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period ...

  4. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta (also known as wild-leg, stinger leg, bastard leg, high-leg, orange-leg, red-leg, dog-leg delta) is a type of electrical service connection for three-phase electric power installations. It is used when both single and three-phase power is desired to be supplied from a three phase transformer (or transformer bank).

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...

  7. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    In electrical engineering, the method of symmetrical components simplifies analysis of unbalanced three-phase power systems under both normal and abnormal conditions. The basic idea is that an asymmetrical set of N phasors can be expressed as a linear combination of N symmetrical sets of phasors by means of a complex linear transformation. [1]

  8. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    A diagram of an electric power system. The transmission system is in blue. Most North American transmission lines are high-voltage three-phase AC, although single phase AC is sometimes used in railway electrification systems. DC technology is used for greater efficiency over longer distances, typically hundreds of miles.

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.

  1. Ads

    related to: 3 phase electrical systems