enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  3. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...

  4. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    These devices, connected in series to the power conductors are typically used to lower the reactive power losses and to increase the amount of active power that can be transmitted through the line, with the supply of reactive power with self-regulation (the supply fortuitously increases with higher load) being the secondary consideration; [12 ...

  5. Power-voltage curve - Wikipedia

    en.wikipedia.org/wiki/Power-voltage_curve

    Power-voltage curve (also P-V curve) describes the relationship between the active power delivered to the electrical load and the voltage at the load terminals in an electric power system under a constant power factor. [1] When plotted with power as a horizontal axis, the curve resembles a human nose, thus it is sometimes called a nose curve. [2]

  6. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    An over-excited synchronous motor has a leading power factor. This makes it useful for power-factor correction of industrial loads. Both transformers and induction motors draw lagging (magnetising) currents from the line. On light loads, the power drawn by induction motors has a large reactive component and the power factor has a low value. The ...

  7. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    The red curve shows the power in the load, normalized relative to its maximum possible. The dark blue curve shows the efficiency η. The efficiency η is the ratio of the power dissipated by the load resistance R L to the total power dissipated by the circuit (which includes the voltage source's resistance of R S as well as R L):

  8. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  9. Zero power factor curve - Wikipedia

    en.wikipedia.org/wiki/Zero_power_factor_curve

    The zero power factor curve (also zero power factor characteristic, ZPF, ZPFC) of a synchronous generator is a plot of the output voltage as a function of the excitation current or field using a zero power factor (purely inductive) load that corresponds to rated voltage at rated current (1 p.u.).