  2. Ground source heat pump - Wikipedia

    en.wikipedia.org/wiki/Ground_source_heat_pump

    A heat pump in combination with heat and cold storage. A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons.

  3. Seasonal thermal energy storage - Wikipedia

    en.wikipedia.org/wiki/Seasonal_thermal_energy...

    A ground source heat pump is used in winter to extract the warmth from the Thermal Bank to provide space heating via underfloor heating. A high Coefficient of performance is obtained because the heat pump starts with a warm temperature of 25 °C (77 °F) from the thermal store, instead of a cold temperature of 10 °C (50 °F) from the ground. [17]

  4. Geothermal heating - Wikipedia

    en.wikipedia.org/wiki/Geothermal_heating

    A ground-source heat pump uses the shallow ground or ground water (typically starting at 10–12 °C or 50–54 °F) as a source of heat, thus taking advantage of its seasonally moderate temperatures. [15] In contrast, an air source heat pump draws heat from the air (colder outside air) and thus requires more energy.

  5. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    Air source heat pumps are the most common models, while other types include ground source heat pumps, water source heat pumps and exhaust air heat pumps. [3] Large-scale heat pumps are also used in district heating systems. [4] The efficiency of a heat pump is expressed as a coefficient of performance (COP), or seasonal coefficient of ...

  6. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    A well designed ground source heat pump installation should achieve an SPF of 3.5, or over 5 if linked to a solar-assisted thermal bank. [6] Example: For a heat pump delivering 120,000,000 BTU during the season, when consuming 15,000 kWh, the HSPF can be calculated as : HSPF = 120000000 (BTU) / (1000) / 15000 (kWh) HSPF = 8

  7. Direct exchange geothermal heat pump - Wikipedia

    en.wikipedia.org/wiki/Direct_exchange_geothermal...

    DX system being drilled in the 1980s. A direct exchange (DX) geothermal heat pump is a type of ground source heat pump in which refrigerant circulates through copper tubing placed in the ground unlike other ground source heat pumps where refrigerant is restricted to the heat pump itself with a secondary loop in the ground filled with a mixture of water and anti-freeze.

  8. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Ground source heat pumps provide a reliable source of consistent thermal energy when buried 10–20 m below the ground surface. The ground temperature is warmer than the ambient air in winter and cooler than the ambient air in summer, providing both a heat source and a heat sink. It was found that in February, the coldest month in the climate ...

  9. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    "Cold climate" heat pumps are designed to optimize efficiency below 0 °F (−18 °C). As of 2023 heat pumps are marketed that will extract heat from outdoor temperatures as low as −40 °F (−40 °C). In the case of cold climates, water or ground-source heat pumps are often the most efficient solution.