enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    The relationship between real power and apparent power is described by the power factor. With a purely resistive load, they are the same: the apparent power is equal to the real power. With a purely resistive load, they are the same: the apparent power is equal to the real power.

  3. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor is defined as the ratio of real power to apparent power. As power is transferred along a transmission line, it does not consist purely of real power that can do work once transferred to the load, but rather consists of a combination of real and reactive power, called apparent power.

  4. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Complex power, S Apparent power, |S| Phase of voltage relative to current, Engineers use the following terms to describe energy flow in a system (and assign each of them a different unit to differentiate between them): Active power, [5] P, or real power: [6] watt (W); Reactive power, Q: volt-ampere reactive (var);

  5. Electric power - Wikipedia

    en.wikipedia.org/wiki/Electric_power

    Real and reactive powers can also be calculated directly from the apparent power, when the current and voltage are both sinusoids with a known phase angle θ between them: = ⁡ = ⁡ The ratio of real power to apparent power is called power factor and is a number always between −1 and 1.

  6. Wattmeter - Wikipedia

    en.wikipedia.org/wiki/Wattmeter

    For each sample, the voltage is multiplied by the current at the same instant; the average over at least one cycle is the real power. The real power divided by the apparent volt-amperes (VA) is the power factor. A computer circuit uses the sampled values to calculate RMS voltage, RMS current, VA, power (watts), power factor, and kilowatt-hours.

  7. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    Power ratings are usually given in watts for real power and volt-amperes for apparent power, although for devices intended for use in large power systems, both may be given in a per-unit system. Cables are usually rated by giving their maximum voltage and their ampacity . [ 4 ]

  8. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The plotted line represents the variation of instantaneous voltage (or current) with respect to time. This cycle repeats with a frequency that depends on the power system. In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period ...

  9. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).