The energy efficiency ratio (EER) of a particular cooling device is the ratio of output cooling energy (in BTUs) to input electrical energy (in watt-hours) at a given operating point. EER is generally calculated using a 95 °F (35 °C) outside temperature and an inside (actually return-air) temperature of 80 °F (27 °C) and 50% relative humidity.
A furnace with a thermal efficiency (η th) of 78% may yield an AFUE of only 64% or so, for example, under the standard's test conditions. When estimating annual or seasonal energy used by combustion devices, the AFUE is the better efficiency measure to use in the calculations. [2]
A realistic indication of energy efficiency over an entire year can be achieved by using seasonal COP or seasonal coefficient of performance (SCOP) for heat. Seasonal energy efficiency ratio (SEER) is mostly used for air conditioning. SCOP is a new methodology which gives a better indication of expected real-life performance of heat pump ...
TEWI was developed by experts at Oak Ridge National Laboratory under contract from Allied Signal (now Honeywell) and was a step forward as a complement and enhancement of previous metrics like coefficient of performance (COP) and Seasonal Energy Efficiency Ratio (SEER), which consider energy use but not global warming potential (GWP) and ...
A heat pump's operating performance in cooling mode is characterized in the US by either its energy efficiency ratio (EER) or seasonal energy efficiency ratio (SEER), both of which have units of BTU/(h·W) (note that 1 BTU/(h·W) = 0.293 W/W) and larger values indicate better performance.
Fuel efficiency (or fuel economy) is a form of thermal efficiency, meaning the ratio of effort to result of a process that converts chemical potential energy contained in a carrier into kinetic energy or work.
The SEER (Seasonal Energy Efficiency Ratio) rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. smoke damper A damper or adjustable louver designed to augment the ventilation of a space during ...
HL = seasonal heat load ≈ 80 GJ/yr for a modern detached house in the northern US; FI = emissions intensity of fuel = 50 kg(CO 2)/GJ for natural gas, 73 for heating oil, 0 for 100% renewable energy such as wind, hydro, photovoltaic or solar thermal; AFUE = furnace efficiency ≈ 95% for a modern condensing furnace