The energy efficiency ratio (EER) of a particular cooling device is the ratio of output cooling energy (in BTUs) to input electrical energy (in watt-hours) at a given operating point. EER is generally calculated using a 95 °F (35 °C) outside temperature and an inside (actually return-air) temperature of 80 °F (27 °C) and 50% relative humidity.
A realistic indication of energy efficiency over an entire year can be achieved by using seasonal COP or seasonal coefficient of performance (SCOP) for heat. Seasonal energy efficiency ratio (SEER) is mostly used for air conditioning. SCOP is a new methodology which gives a better indication of expected real-life performance of heat pump ...
A similar standard in the United States is the integrated energy efficiency ratio (IEER). The ESEER is calculated by combining full and part load operating Energy Efficiency Ratios (EER), for different seasonal air or water temperatures, and including for appropriate weighting factors. These values are shown in the following table.
The process for determining star ratings differs between various categories. For instance, the BEE had announced in 2016 that it would be switching to ISEER (Indian Seasonal Energy Efficiency Ratio) to calculate star ratings for air conditioners. This is an evolution of the SEER method used in the US.
A new energy label, introduced in 2010, is based on the energy efficiency index (EEI), and has energy classes in the range A+++ to D. [11] The EEI is a measure of the annual electricity consumption, and includes energy consumed during power-off and standby modes, and the energy consumed in 220 washing cycles. For the washing cycles, a weighted ...
Heating seasonal performance factor (HSPF) is a term used in the heating and cooling industry. HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU ...
A furnace with a thermal efficiency (η th) of 78% may yield an AFUE of only 64% or so, for example, under the standard's test conditions. When estimating annual or seasonal energy used by combustion devices, the AFUE is the better efficiency measure to use in the calculations. [2]
European Commission definitions of energy efficiency, [2] are given below: Energy efficiency — a ratio between an output of performance, service, goods or energy, and an input of energy; Energy efficiency improvement — an increase in energy end-use efficiency as a result of technological, behavioural and/or economic changes;