enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electron capture detector - Wikipedia

    en.wikipedia.org/wiki/Electron_capture_detector

    The answer is recombination of negative ions or electrons with the positive ions of the makeup gas before these charged entities can be collected at anode and cathode respectively. Negative and positive ions recombine much more rapidly than electrons and positive ions; it is this more rapid neutralization that is the origin of the observed ...

  3. Gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography

    Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]

  4. Thermal conductivity detector - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_detector

    The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...

  5. Chromatography - Wikipedia

    en.wikipedia.org/wiki/Chromatography

    Pyrolysis–gas chromatography–mass spectrometry is a method of chemical analysis in which the sample is heated to decomposition to produce smaller molecules that are separated by gas chromatography and detected using mass spectrometry. Pyrolysis is the thermal decomposition of materials in an inert atmosphere or a vacuum.

  6. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...

  7. Nitrogen–phosphorus detector - Wikipedia

    en.wikipedia.org/wiki/Nitrogen–phosphorus_detector

    The nitrogen–phosphorus detector (NPD) is also known as thermionic specific detector (TSD) is a detector commonly used with gas chromatography, in which thermal energy is used to ionize an analyte. [ 1 ] [ 2 ] It is a type of flame thermionic detector (FTD), the other being the alkali flame-ionization detector (AFID also known as AFD).

  8. Direct analysis in real time - Wikipedia

    en.wikipedia.org/wiki/Direct_analysis_in_real_time

    Gas chromatography has been carried out by coupling gas chromatography columns directly into the DART gas stream through a heated interface. Eluate from a high-pressure liquid chromatograph ( HPLC ) can be also introduced to the reaction zone of the DART source and analyze.

  9. Headspace gas chromatography for dissolved gas measurement

    en.wikipedia.org/wiki/Headspace_Gas...

    One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...