enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Color calibration - Wikipedia

    en.wikipedia.org/wiki/Color_calibration

    Color calibration of a monitor using ColorHug2, an open source colorimeter, placed on the screen. For calibrating the monitor a colorimeter is attached flat to the display's surface, shielded from all ambient light. The calibration software sends a series of color signals to the display and compares the values that were actually sent against ...

  3. Colorimetry (chemical method) - Wikipedia

    en.wikipedia.org/wiki/Colorimetry_(chemical_method)

    A colorimeter is a device used to test the concentration of a solution by measuring its absorbance of a specific wavelength of light. To use this device, different solutions must be made, and a control (usually a mixture of distilled water and another solution) is first filled into a cuvette and placed inside a colorimeter to calibrate the machine.

  4. Colorimeter (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Colorimeter_(chemistry)

    A colorimeter is a device used in colorimetry that measures the absorbance of particular wavelengths of light by a specific solution. [1] [2] It is commonly used to determine the concentration of a known solute in a given solution by the application of the Beer–Lambert law, which states that the concentration of a solute is proportional to the absorbance.

  5. Colorimetric analysis - Wikipedia

    en.wikipedia.org/wiki/Colorimetric_analysis

    The equipment required is a colorimeter, some cuvettes and a suitable color reagent. The process may be automated, e.g. by the use of an AutoAnalyzer or by flow injection analysis . Recently, colorimetric analyses developed for colorimeters have been adapted for use with plate readers to speed up analysis and reduce the waste stream.

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. ColorChecker - Wikipedia

    en.wikipedia.org/wiki/ColorChecker

    The ColorChecker Classic chart is a rectangular card measuring about 11 by 8.25 inches (27.9 by 21.0 cm), or in its original incarnation about 13 by 9 inches (33 by 23 cm), an aspect ratio approximately the same as that of 35 mm film. [5]

  8. Ostwald color system - Wikipedia

    en.wikipedia.org/wiki/Ostwald_color_system

    The Color Harmony Manual is made up of charts of colored chips representing a color space. The overall shape of a chart is an equilateral triangle made up of 28 samples. Each chart is made up of samples of approximately the same hue. Each chart has one sample with the greatest purity. This sample is the far point of the triangle.

  9. Colorimetry - Wikipedia

    en.wikipedia.org/wiki/Colorimetry

    Colorimetry is "the science and technology used to quantify and describe physically the human color perception". [1] It is similar to spectrophotometry, but is distinguished by its interest in reducing spectra to the physical correlates of color perception, most often the CIE 1931 XYZ color space tristimulus values and related quantities.