Search results
Results from the WOW.Com Content Network
Spray foam insulation or spray polyurethane foam (SPF) is an alternative to traditional building insulation such as fiberglass. A two-component mixture composed of isocyanate and polyol resin comes together at the tip of a gun, and forms an expanding foam that is sprayed onto roof tiles, concrete slabs, into wall cavities, or through holes ...
Sealection 500 spray foam R-3.8 (RSI-0.67) per inch. [14] a water-blown low density spray polyurethane foam that uses water in a chemical reaction to create carbon dioxide and steam which expands the foam. Flame spread is 21 and smoke developed is 217 which makes it a Class I material (best fire rating). Disadvantages: Is an Isocyanate.
Spray gypsum-based plaster fireproofing being installed. Circuit integrity fireproofing of cable trays, using calcium silicate boards. Damaged spray fireproofing. Fireproofing is rendering something (structures, materials, etc.) resistant to fire, or incombustible; or material for use in making anything fire-proof. [1]
Bulk insulators block conductive heat transfer and convective flow either into or out of a building. Air is a very poor conductor of heat and therefore makes a good insulator. Insulation to resist conductive heat transfer uses air spaces between fibers, inside foam or plastic bubbles and in building cavities like the attic.
The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...
Power trowels differ in the way they are controlled: Ride-on power trowels have two spider/rotor assemblies and are controlled by an operator sitting on a seat upon the machine, controlling the power trowel movement with two joystick/levers (these can be either mechanical or electronic/hydraulic).
A deluge gun can discharge 7,500 litres (2,000 US gal) per minute or more. A master stream is a fire service term for a water stream of 1,250 litres (330 US gal) per minute or greater. It is delivered by a master stream device, such as a deck gun, deluge gun, or fire monitor.
It was first invented in 1955 by H.B. Sargent, R.M. Poorman and H. Lamprey and is applied to a component using a specifically designed detonation gun (D-gun). The component being sprayed must be prepared correctly by removing all surface oils, greases, debris and roughing up the surface in order to achieve a strongly bonded detonation spray ...