  2. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same ...

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.

  4. Eddy-current testing - Wikipedia

    en.wikipedia.org/wiki/Eddy-current_testing

    Variations in the electrical conductivity and magnetic permeability of the test object, and the presence of defects causes a change in eddy current and a corresponding change in phase and amplitude that can be detected by measuring the impedance changes in the coil, which is a telltale sign of the presence of defects. [5]

  5. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  6. Fault detection and isolation - Wikipedia

    en.wikipedia.org/wiki/Fault_detection_and_isolation

    The time frequency approach for machine fault diagnosis can be divided into two broad categories: linear methods and the quadratic methods. The difference is that linear transforms can be inverted to construct the time signal, thus, they are more suitable for signal processing, such as noise reduction and time-varying filtering.

  7. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    Murray loop test employs the principle of wheatstone bridge for locating the fault. To perform this test, it is necessary to have a sound cable running alongside the faulty cable. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted.

  8. Wafer bond characterization - Wikipedia

    en.wikipedia.org/wiki/Wafer_bond_characterization

    Double cantilever beam test, also referred to as crack opening or razor blade method, is a method to define the strength of the bond. This is achieved by determining the energy of the bonded surfaces. A blade of a specific thickness is inserted between the bonded wafer pair. This leads to a split-up of the bond connection. [3]

  9. Troubleshooting - Wikipedia

    en.wikipedia.org/wiki/Troubleshooting

    Troubleshooting is a form of problem solving, often applied to repair failed products or processes on a machine or a system.It is a logical, systematic search for the source of a problem in order to solve it, and make the product or process operational again.