  2. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  3. Ferroresonance in electricity networks - Wikipedia

    en.wikipedia.org/wiki/Ferroresonance_in...

    The phenomenon can be avoided by connecting a minimal resistive load on the transformer secondaries or by interrupting the applied voltage by a 3-phase interrupting device such as a ganged (3-pole) circuit breaker. [8] In many cases, it also suffices to unground the transformer in a Δ configuration, which increases the line shunt impedance.

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In a "ground fault" or "earth fault", current flows into the earth. The prospective short-circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.

  5. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    A sudden fail-open fault can cause multiple secondary failures if it is fast and the circuit contains an inductance; this causes large voltage spikes, which may exceed 500 volts. A broken metallisation on a chip may thus cause secondary overvoltage damage. [1] Thermal runaway can cause sudden failures including melting, fire or explosions.

  6. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    At two multiples of the rated current, the recloser's rapid trip curve can cause a trip (off circuit) in as little as 1.5 cycles (or 30 milliseconds). During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current.

  7. Voltage sag - Wikipedia

    en.wikipedia.org/wiki/Voltage_sag

    A voltage sag (U.S. English) or voltage dip [1] (British English) is a short-duration reduction in the voltage of an electric power distribution system. It can be caused by high current demand such as inrush current (starting of electric motors, transformers, heaters, power supplies) or fault current (overload or short circuit) elsewhere on the system.

  8. Are Dogs Lactose Intolerant? What Experts Advise About ...

    www.aol.com/dogs-lactose-intolerant-experts...

    Not all questions have simple, yes or no answers—including this one. While many dogs are lactose intolerant, many are not! Lactose intolerance develops as a dog grows up, so it can be impossible ...

  9. Brownout (electricity) - Wikipedia

    en.wikipedia.org/wiki/Brownout_(electricity)

    Brownouts can cause unexpected behavior in systems with digital control circuits. Reduced voltages can bring control signals below the threshold at which logic circuits can reliably detect which state is being represented.