A floating ground is a reference point for electrical potential in a circuit which is galvanically isolated from actual earth ground. Most electrical circuits have a ground which is electrically connected to the Earth, hence the name "ground". The ground is said to be floating when this connection does not exist. [1]
English: Active indirect water heater. 1: Municipal water feed 2: Fluid from water storage tank to external (passive) heat source; passive heat source can be the ground (soil or groundwater), sun or air; eg via heat pump, or thermodynamic solar panel 3: Fluid from heat pump, or thermodynamic solar panel to water storage tank 4: Pump, actuator, controller and other parts 5: Water heater 6 ...
Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1] Leg as in "hot leg" refers to one of multiple hot conductors in an electrical system.
The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]
An automotive wiring diagram, showing useful information such as crimp connection locations and wire colors. These details may not be so easily found on a more schematic drawing. A wiring diagram is a simplified conventional pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes, and the ...
A poorly installed system with old aluminum wires, bad connections or an unconnected ground wire (which is often the case) may be dangerous, as the wires can overheat or electric current may leak via the water stream through the body of the user to earth. [3]
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.