The type of oxygen sensor used in most underwater diving applications is the electro-galvanic oxygen sensor, a type of fuel cell, which is sometimes called an oxygen analyser or ppO 2 meter. They are used to measure the oxygen concentration of breathing gas mixes such as nitrox and trimix . [ 9 ]
There are two commonly used ways to specify expected sensor life span: The time in months at room temperature in air, or volume percentage oxygen hours (Vol%O 2 h). Storage at low oxygen partial pressure when not in use would seem an effective way to extend cell life, but when stored in anoxic conditions the sensor current will cease and the ...
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
Arterial blood oxygen tension (normal) P a O 2 – Partial pressure of oxygen at sea level (160 mmHg in the atmosphere, 21% of standard atmospheric pressure of 760 mmHg) in arterial blood is between 75 mmHg and 100 mmHg. [4] [5] [6] Venous blood oxygen tension (normal) P v O 2 – Oxygen tension in venous blood at sea level is between 30 mmHg ...
The alveolar oxygen partial pressure is lower than the atmospheric O 2 partial pressure for two reasons. Firstly, as the air enters the lungs, it is humidified by the upper airway and thus the partial pressure of water vapour (47 mmHg) reduces the oxygen partial pressure to about 150 mmHg.
A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.
Under most conditions, the partial pressure of carbon dioxide (PCO 2), or concentration of carbon dioxide, controls the respiratory rate. The peripheral chemoreceptors that detect changes in the levels of oxygen and carbon dioxide are located in the arterial aortic bodies and the carotid bodies. [2]
Portable oxygen concentrator used with bottle humidifier. POCs operate on the same principle as a home concentrator, pressure swing adsorption. [6] The basic set up of a POC is a miniaturized air compressor, a cylinder filled containing the sieve, a pressure equalizing reservoir and valves and tubes.