enow.com Web Search

  1. Ads

    related to: should bipap have o2 influx devices and oxygen tanks and pumps

Search results

  1. Results from the WOW.Com Content Network
  2. Flow-restricted, oxygen-powered ventilation device - Wikipedia

    en.wikipedia.org/wiki/Flow-restricted,_oxygen...

    The (FROPVD) has a peak flow rate of 100% oxygen at up to 40 liters per minute. To use the device, manually trigger it until chest rise is noted and then release. [2] Wait five seconds before repeating. The device must have a pressure relief valve that opens at 60cm of water pressure to avoid over ventilation and trauma to the lungs.

  3. Positive airway pressure - Wikipedia

    en.wikipedia.org/wiki/Positive_airway_pressure

    Positive airway pressure (PAP) is a mode of respiratory ventilation used in the treatment of sleep apnea.PAP ventilation is also commonly used for those who are critically ill in hospital with respiratory failure, in newborn infants (), and for the prevention and treatment of atelectasis in patients with difficulty taking deep breaths.

  4. Airway pressure release ventilation - Wikipedia

    en.wikipedia.org/wiki/Airway_pressure_release...

    The term APRV has also been used in American journals where, from the ventilation characteristics, BIPAP would have been the appropriate terminology. [14] To further confusion, BiPAP is a registered trade-mark for a noninvasive ventilation mode in a specific ventilator (Respironics Inc.).

  5. Continuous positive airway pressure - Wikipedia

    en.wikipedia.org/wiki/Continuous_positive_airway...

    However, while PEEP refers to devices that impose positive pressure only at the end of the exhalation, CPAP devices apply continuous positive airway pressure throughout the breathing cycle. Thus, the ventilator does not cycle during CPAP, no additional pressure greater than the level of CPAP is provided, and patients must initiate all of their ...

  6. Bag valve mask - Wikipedia

    en.wikipedia.org/wiki/Bag_valve_mask

    A bag valve mask can be used without being attached to an oxygen tank to provide "room air" (21% oxygen) to the patient. However, manual resuscitator devices also can be connected to a separate bag reservoir, which can be filled with pure oxygen from a compressed oxygen source, thus increasing the amount of oxygen delivered to the patient to ...

  7. Breathing apparatus - Wikipedia

    en.wikipedia.org/wiki/Breathing_apparatus

    An oxygen concentrator is a device that concentrates the oxygen from a gas supply (typically ambient air) by selectively removing nitrogen to supply an oxygen-enriched product gas stream. They are also used industrially and as medical devices for oxygen therapy. [58] Two methods in common use are pressure swing adsorption and membrane gas ...

  8. Ventilator - Wikipedia

    en.wikipedia.org/wiki/Ventilator

    Ventilators may also be equipped with monitoring and alarm systems for patient-related parameters (e.g., pressure, volume, and flow) and ventilator function (e.g., air leakage, power failure, mechanical failure), backup batteries, oxygen tanks, and remote control. The pneumatic system is nowadays often replaced by a computer-controlled turbopump.

  9. Resuscitator - Wikipedia

    en.wikipedia.org/wiki/Resuscitator

    A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. [citation needed] There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank.

  1. Ads

    related to: should bipap have o2 influx devices and oxygen tanks and pumps