Search results
Results from the WOW.Com Content Network
This "global" detection limit (including all the steps of the analysis method) is called the method detection limit (MDL). The practical way for determining the MDL is to analyze seven samples of concentration near the expected limit of detection. The standard deviation is then determined.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The odor detection threshold is the lowest concentration of a certain odor compound that is perceivable by the human sense of smell. The threshold of a chemical compound is determined in part by its shape , polarity , partial charges , and molecular mass .
Using a spectrophotometer, it is possible to quantitatively determine the nitrite concentration. The detection limit of the Griess test generally ranges between 0.02 and 2 μM, depending on the exact details of the specific components used in the Griess reagent. [3]
Threshold limit value − short-term exposure limit (TLV-STEL): A 15-minute TWA exposure that should not be exceeded at any time during a workday, even if the 8-hour TWA is within the TLV-TWA. Threshold limit value - surface limit (TLV-SL): Supplements airborne TLVs by establishing a concentration on a surface that is not likely to cause an ...
Stripping analysis has the following properties: sensitive and reproducible (RSD<5%) method for trace metal ion analysis in aqueous media, 2) concentration limits of detection for many metals are in the low ppb to high ppt range (S/N=3) and this compares favorably with AAS or ICP analysis, field deployable instrumentation that is inexpensive ...
Tunable diode laser absorption spectroscopy (TDLAS, sometimes referred to as TDLS, TLS or TLAS [1]) is a technique for measuring the concentration of certain species such as methane, water vapor and many more, in a gaseous mixture using tunable diode lasers and laser absorption spectrometry.
Considering detection limit, both TCD and FID reach low concentration levels (inferior to ppm or ppb). [2] Both of them require pressurized carrier gas (Typically: H 2 for FID, He for TCD) but due to the risk associated with storing H 2 (high flammability, see Hydrogen safety), TCD with He should be considered in locations where safety is crucial.