An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay. The ANSI device number is 50 for an IOC relay or a DTOC relay. In a typical application, the over current relay is connected to a ...
50 – Instantaneous Overcurrent (N for neutral, G for ground current) 51 – Inverse Time Overcurrent (N for neutral, G from ground current) 59 – Over Voltage; 62 – Timer; 64 – Ground Fault (64F = Field Ground, 64G = Generator Ground) 67 – Directional Over Current (typically controls a 50/51 element) 79 – Reclosing Relay
50/51 - Instantaneous / Time-delay Overcurrent relay; 50/74 - CT Trouble; 50/87 - Instantaneous Differential; 51 - AC Time Overcurrent Relay; 51C - Voltage Controlled Time Overcurrent; 51G - Ground Time Overcurrent; 51LR - AC Inverse Time Overcurrent (Locked Rotor) Protection Relay; 51N - Neutral Time Overcurrent; 51P - Phase Time Overcurrent
Instantaneous overcurrent requires that the current exceeds a predetermined level for the circuit breaker to operate. Time overcurrent protection operates based on a current vs time curve. Based on this curve, if the measured current exceeds a given level for the preset amount of time, the circuit breaker or fuse will operate.
According to the 2020 NEC/NFPA 70, a current-limiting overcurrent protective device is defined as, "A device that, when interrupting currents in its current-limiting range, reduces the current flowing in the faulted circuit to a magnitude substantially less than that obtainable in the same circuit if the device were replaced with a solid ...
An optional time delay circuit that controls the timing of the switch action after the input has reached the threshold; A power supply for the static relay circuits; For example, an overcurrent protective relay may have an AC to DC power supply for the input circuit, a level detector circuit and an RC time delay circuit. [1]
Federico Arellano is a U.S. citizen and says three of his four children are too. He says the situation is a misunderstanding and that his family was misled before being deported.
Lack of overcurrent capability (low short circuit ratio) of a weak grid creates a multitude of problems, including: [2] transients during the large load changes will cause large variations of the grid voltage, causing problems with the loads (e.g., some motors might not be able to start in the undervoltage condition);