  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.

  4. European seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/European_seasonal_energy...

    In the United Kingdom, a Seasonal Energy Efficiency ratio (SEER) for refrigeration and air conditioning products, similar to the ESEER but with different load profile weighting factors, is used for part of the Building Regulations Part L calculations within the Simplified Building Energy Model (SBEM) software, and are used in the production of Energy Performance Certificates (EPC) for new ...

  5. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    The SEER rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is the ratio of cooling in British thermal units (BTUs) to the energy consumed in watt-hours.

  6. Exergy efficiency - Wikipedia

    en.wikipedia.org/wiki/Exergy_efficiency

    For example, for HVAC systems seeking to cool and dehumidify, it is reasonable to define their second law efficiencies for cooling and dehumidification by calculating exergy changes of all incoming and outgoing air and water streams, while assuming a target supply air temperature and humidity. [3]

  7. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  8. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  9. Logarithmic mean temperature difference - Wikipedia

    en.wikipedia.org/wiki/Logarithmic_mean...

    When the two temperature differences are equal, this formula does not directly resolve, so the LMTD is conventionally taken to equal its limit value, which is in this case trivially equal to the two differences. With this definition, the LMTD can be used to find the exchanged heat in a heat exchanger: