  2. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    A significant drop of pressure in a water delivery system creates a similar suction, pulling possibly undesirable material into the system. This is an example of an indirect cross-connection . Back-pressure occurs for example when air is blown through the straw and bubbles begin to erupt at the submerged end.

  3. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Backflow occurs for one of two reasons, either back pressure or back siphonage. [1] Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure.

  4. Trap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Trap_(plumbing)

    Trap with copper drain pipe at underside of firestop packing in two-hour fire-resistance rated concrete floor slab Typical P-trap. Maintaining the water seal is critical to trap operation; traps might dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap ...

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1] [2] reduced pressure zone assemblies (RPZA), [3] or reduced pressure principle ...

  6. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  7. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test pressure. Pressure tightness can be tested by shutting off the supply valve and observing whether there is a pressure loss.

  8. Florida residents at newly-opened apartments are being ... - AOL

    www.aol.com/finance/florida-residents-newly...

    The drastic measure came after an issue with the flooring, which is uneven in every unit above the first floor and, in some cases, even sinks under the weight of normal couches and other furniture.

  9. Trap primer - Wikipedia

    en.wikipedia.org/wiki/Trap_primer

    A trap primer (or trap seal primer) is a plumbing device or valve that adds water to traps.The water seals in traps are needed to prevent sewer gases from entering buildings, but because this water is exposed to the air, it is subject to evaporation over time in infrequently used floor drains, leading to the release of sewer gas into the environment.