enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The probe is placed on the pre-corneal tear film on the central cornea (see gallery) and the integrated piezoresistive pressure sensor automatically begins to acquire data, measuring IOP 100 times per second. The tonometer tip rests on the cornea with a constant appositional force of one gram.

  3. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  4. List of instruments used in ophthalmology - Wikipedia

    en.wikipedia.org/wiki/List_of_instruments_used...

    Castroveijo's corneal trephine: used in corneal donation (eye donation) to cut out the cornea in a circular fashion Pin-hole: testing visual acuity Red green goggles (red - right side & green - left side) used in Worth 4 dot test, diplopia testing Prisms: to measure the degree of squints; in other instruments; refractive correction; etc ...

  5. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  6. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    open angle between cornea and iris AC 3/4: Grade 3 anterior chamber angle: AC 2/4: Grade 2 anterior chamber angle: AC 1/4: Grade 1 anterior chamber angle: AC 0/4: Grade 0 anterior chamber angle: closed angle between cornea and iris AC/A: Accommodative convergence / Accommodation ratio the portion of the range of convergence that occurs in ...

  7. Radial keratotomy - Wikipedia

    en.wikipedia.org/wiki/Radial_keratotomy

    One study cites incisions made to a depth equivalent to the thinnest of four corneal-thickness measurements made near the center of the cornea. [4] Other sources cite surgeries leaving 20 to 50 micrometres of corneal tissue unincised (roughly equivalent to 90% of corneal depth, based on thickness norms). [3]

  8. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    To simplify the calculation, the cornea is assumed to be a thin spherical lens with a fixed anterior to posterior corneal curvature ratio and an index of refraction of 1.3375. Central corneal power can be measured by keratometry or corneal topography. Corneal radius of curvature relates to corneal power with the equation: r = 337.5/K. [3]

  9. Phakic intraocular lens - Wikipedia

    en.wikipedia.org/wiki/Phakic_intraocular_lens

    Phakic intraocular lenses are indicated for patients with high refractive errors when the usual laser options for surgical correction (LASIK and PRK) are contraindicated. [ 1 ] [ 2 ] Phakic IOLs are designed to correct high myopia ranging from −5 to −20 D if the patient has enough anterior chamber depth (ACD) of at least 3 mm. [ 3 ]