enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    The task of additional reactive power compensation (also known as voltage compensation) is assigned to compensating devices: [7] passive (either permanently connected or switched) sinks of reactive power (e.g., shunt reactors that are similar to transformers in construction, with a single winding and iron core [9]).

  3. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    The main advantage of SVCs over simple mechanically switched compensation schemes is their near-instantaneous response to changes in the system voltage. [7] For this reason they are often operated at close to their zero-point in order to maximize the reactive power correction they can rapidly provide when required.

  4. Unified power flow controller - Wikipedia

    en.wikipedia.org/wiki/Unified_Power_Flow_Controller

    A unified power flow controller (UPFC) is an electrical device for providing fast-acting reactive power compensation on high-voltage electricity transmission networks. It uses a pair of three-phase controllable bridges to produce current that is injected into a transmission line using a series transformer. [ 1 ]

  5. Static synchronous compensator - Wikipedia

    en.wikipedia.org/wiki/Static_synchronous_compensator

    In Electrical Engineering , a static synchronous compensator (STATCOM) is a shunt-connected, reactive compensation device used on transmission networks. It uses power electronics to form a voltage-source converter that can act as either a source or sink of reactive AC power to an electricity network.

  6. Thyristor-switched capacitor - Wikipedia

    en.wikipedia.org/wiki/Thyristor-switched_capacitor

    Unlike the TCR, the TSC is only ever operated fully on or fully off. An attempt to operate a TSC in ‘’phase control’’ would result in the generation of very large amplitude resonant currents, leading to overheating of the capacitor bank and thyristor valve, and harmonic distortion in the AC system to which the SVC is connected.

  7. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    Heavily loaded lines consumed reactive power due to the line's inductance, and as transmission voltage increased throughout the 20th century, the higher voltage supplied capacitive reactive power. As operating a transmission line only at it surge impedance loading (SIL) was not feasible, [2] other means to manage the reactive power was needed.

  8. Thyristor-controlled reactor - Wikipedia

    en.wikipedia.org/wiki/Thyristor-controlled_reactor

    The current in the TCR is varied from maximum (determined by the connection voltage and the inductance of the reactor) to almost zero by varying the "Firing Delay Angle", α. α is defined as the delay angle from the point at which the voltage becomes positive to the point at which the thyristor valve is turned on and current starts to flow.

  9. Dynamic voltage restoration - Wikipedia

    en.wikipedia.org/wiki/Dynamic_Voltage_Restoration

    In other words, the DVR is a solid state DC to AC switching power converter that injects a set of three-phase AC output voltages in series and synchronicity with the distribution and transmission line voltages. The source of the injected voltage is the commutation process for reactive power demand and an energy source for the real power demand.