enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Capacity credit - Wikipedia

    en.wikipedia.org/wiki/Capacity_credit

    The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added).

  3. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    Generally base values of power and voltage are chosen. The base power may be the rating of a single piece of apparatus such as a motor or generator. If a system is being studied, the base power is usually chosen as a convenient round number such as 10 MVA or 100 MVA. The base voltage is chosen as the nominal rated voltage of the system.

  5. State of charge - Wikipedia

    en.wikipedia.org/wiki/State_of_charge

    State of charge (SoC) quantifies the remaining capacity available in a battery at a given time and in relation to a given state of ageing. [1] It is usually expressed as percentage (0% = empty; 100% = full). An alternative form of the same measure is the depth of discharge , calculated as 1 −

  6. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  7. Nominal power (photovoltaic) - Wikipedia

    en.wikipedia.org/wiki/Nominal_power_(photovoltaic)

    The nominal power of PV devices is measured under standard test conditions (STC), specified in standards such as IEC 61215, IEC 61646 and UL 1703. Specifically, the light intensity is 1000 W/m 2, with a spectrum similar to sunlight hitting the Earth's surface at latitude 35°N in the summer (airmass 1.5), the temperature of the cells being 25 °C.

  8. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    If a plant is only needed during the day, for example, even if it operates at full power output from 8 am to 8 pm every day (12 hours) all year long, it would only have a 50% capacity factor. Due to low capacity factors, electricity from peaking power plants is relatively expensive because the limited generation has to cover the plant fixed costs.

  9. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    For AC-operated devices (e.g. coaxial cable, loudspeakers), there may even be two power ratings, a maximum (peak) power rating and an average power rating. [ 5 ] [ 6 ] For such devices, the peak power rating usually specifies the low frequency or pulse energy, while the average power rating limits high-frequency operation. [ 5 ]