Search results
Results from the WOW.Com Content Network
Double layer of 1 ⁄ 2-inch (13 mm) drywall on each side, wood studs, batt insulation in wall 46 Single layer of 1 ⁄ 2-inch (13 mm) drywall, glued to 6-inch (150 mm) lightweight concrete block wall, painted both sides 46 6-inch (150 mm) hollow CMU (concrete masonry unit) [34] 48 8-inch (200 mm) hollow CMU (concrete masonry unit) [34] 50
A pallet of "8-inch" concrete blocks An interior wall of painted concrete blocks Concrete masonry blocks A building constructed with concrete masonry blocks. A concrete block, also known as a cinder block in North American English, breeze block in British English, or concrete masonry unit (CMU), or by various other terms, is a standard-size rectangular block used in building construction.
Standard thickness ICF walls have shown sound transmission coefficients (STC) between 46 and 72 compared to 36 for standard fiberglass insulation and drywall. The level of sound attenuation achieved is a function of wall thickness, mass, component materials and air tightness.
The average thermal insulance of the "bridged" layer depends upon the fraction of the area taken up by the mortar in comparison with the fraction of the area taken up by the light concrete blocks. To calculate thermal transmittance when there are "bridging" mortar joints it is necessary to calculate two quantities, known as R max and R min .
The sound reduction index is used to measure the level of sound insulation provided by a structure such as a wall, window, door, or ventilator. It is defined in the series of international standards ISO 16283 (parts 1-3) and the older ISO 140 (parts 1-14), or the regional or national variants on these standards.
[57] [58] Masonry drill bits and standard expandable wall plugs are not suitable for use with AAC blocks. [58] Using European standard density (400 kg/m 3, B2,5), AAC blocks alone would require very thick — 500mm or thicker — walls to achieve the insulation levels required by newer building codes in Northern Europe. [55]
This is the simplest arrangement of masonry units. If the wall is two wythes thick, one header is used to bind the two wythes together. [3] Header course: This is a course made up of a row of headers. [1] Bond course: This is a course of headers that bond the facing masonry to the backing masonry. [1] Plinth: The bottom course of a wall.
Exterior insulation and finish system (EIFS) is a general class of non-load bearing building cladding systems that provides exterior walls with an insulated, water-resistant, finished surface in an integrated composite material system. EIFS has been in use since the 1960s in North America and was first used on