Search results
Results from the WOW.Com Content Network
The standard penetration test (SPT) is an in-situ dynamic penetration test designed to provide information on the geotechnical engineering properties of soil. This test is the most frequently used subsurface exploration drilling test performed worldwide. The test procedure is described in ISO 22476-3, ASTM D1586 [1] and Australian Standards AS ...
It necessitates the test of surge immunity in electrical or electronic equipment. IEC 61000-4-5 defines test set-up, procedures, and classification levels. In particular, it standardizes the required surge voltage and current waveforms for laboratory testing, with the "1.2/50-8/20 μs" impulse being the most frequently used surge waveform.
For capacitances following the (E3, E6, E12 or) E24 series of preferred values, the former ANSI/EIA-198-D:1991, ANSI/EIA-198-1-E:1998 and ANSI/EIA-198-1-F:2002 as well as the amendment IEC 60062:2016/AMD1:2019 to IEC 60062 define a special two-character marking code for capacitors for very small parts which leave no room to print any longer ...
A line impedance stabilization network (LISN) [1] is a device used in conducted and radiated radio-frequency emission and susceptibility tests, as specified in various electromagnetic compatibility (EMC)/EMI test standards (e.g., by CISPR, International Electrotechnical Commission, CENELEC, U.S. Federal Communications Commission, MIL-STD, DO-160 Sections 20-21-22).
The test method consists of pushing an instrumented cone, with the tip facing down, into the ground at a controlled rate (controlled between 1.5 -2.5 cm/s accepted). The resolution of the CPT in delineating stratigraphic layers is related to the size of the cone tip, with typical cone tips having a cross-sectional area of either 10 or 15 cm 2 ...
Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.
The modified hole erosion test (HET-P) seeks to rectify these issues with the addition of a pitot-static tube. [4] This allows for the direct measurement of total hydraulic head, thus accounting for the total energy loss between the upstream and downstream ends of the soil sample.
The method consists of filling the flow area with stream and equipotential lines, which are everywhere perpendicular to each other, making a curvilinear grid.Typically there are two surfaces (boundaries) which are at constant values of potential or hydraulic head (upstream and downstream ends), and the other surfaces are no-flow boundaries (i.e., impermeable; for example the bottom of the dam ...