enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    These switches appear externally similar to single pole, single throw (SPST) switches, but have extra connections which allow a circuit to be controlled from multiple locations. Toggling the switch disconnects one "traveler" terminal and connects the other. Electrically, a typical "3-way" switch is a single pole, double throw (SPDT) switch. By ...

  3. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Even when unmarked, it is generally easy to identify this type of system, because the B phase (circuits #3 and #4) and every third circuit afterwards will be either a three-pole breaker or a blank. Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V ...

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    This three-wire single-phase system is common in North America for residential and light commercial applications. Circuit breaker panels typically have two live (hot) wires, and a neutral, connected at one point to the grounded center tap of a local transformer. Usually, one of the live wires is black and the other one red; the neutral wire is ...

  5. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    The kit achieves the same function by adding an external interlock onto an existing breaker panel that allows the main breaker to be turned on or one designated load breaker to be turned on, but not both at the same time. The interlocked load breaker is repurposed as the "backfeed" breaker, and a generator is connected to it (wired directly or ...

  6. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The earliest standardized method of wiring in buildings, in common use in North America from about 1880 to the 1930s, was knob and tube (K&T) wiring: single conductors were run through cavities between the structural members in walls and ceilings, with ceramic tubes forming protective channels through joists and ceramic knobs attached to the ...

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    Simplified single line diagram of a single-phase transfer switch to select either 'city' (utility) power or local generator power 3-phase Intelligent transfer switch. A transfer switch is an electrical switch that switches a load between two sources. Some transfer switches are manual, in that an operator effects the transfer by throwing a ...

  9. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    In the US, where split-phase supplies are common, in a branch circuit with more than one live conductor, each live conductor must be protected by a breaker pole. To ensure that all live conductors are interrupted when any pole trips, a common-trip set of breakers must be used. These may either contain two or three tripping mechanisms within one ...