enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrophysiology - Wikipedia

    en.wikipedia.org/wiki/Electrophysiology

    Electrophysiology (from Greek ... "Current Clamp" is a common technique in electrophysiology. This is a whole-cell current clamp recording of a neuron firing due to ...

  3. Patch clamp - Wikipedia

    en.wikipedia.org/wiki/Patch_clamp

    Alternatively, the current clamp technique can be used. In this case, the current passing across the membrane is controlled by the experimenter and the resulting changes in voltage are recorded, generally in the form of action potentials. Erwin Neher and Bert Sakmann developed the patch clamp in the late 1970s and early 1980s. This discovery ...

  4. Automated patch clamp - Wikipedia

    en.wikipedia.org/wiki/Automated_patch_clamp

    Patch-clamp automation instrumentation became commercially available in 2003. Due to the initial high cost this near to 20 years old technology was originally intended to serve the biotech and pharmaceutical industries but it has since also been used in academia and nonprofit settings, in connection and coexisting with other associated or ...

  5. Cellular neuroscience - Wikipedia

    en.wikipedia.org/wiki/Cellular_neuroscience

    "Current Clamp" is a common technique in electrophysiology. This is a whole cell current clamp recording of a neuron firing a train of action potentials due to it being depolarized by current injection

  6. Voltage clamp - Wikipedia

    en.wikipedia.org/wiki/Voltage_clamp

    Voltage and current errors: SEV-c circuitry does not actually measure the voltage of the cell being clamped (as does a two-electrode clamp). The patch-clamp amplifier is like a two-electrode clamp, except the voltage measuring and current passing circuits are connected (in the two-electrode clamp, they are connected through the cell). The ...

  7. Single-unit recording - Wikipedia

    en.wikipedia.org/wiki/Single-unit_recording

    This current creates a measurable, changing voltage potential within (and outside) the cell. This allows for two basic types of single-unit recordings. Intracellular single-unit recordings occur within the neuron and measure the voltage change (with respect to time) across the membrane during action potentials.

  8. Category:Electrophysiology - Wikipedia

    en.wikipedia.org/wiki/Category:Electrophysiology

    Automated patch clamp; B. Ball and chain inactivation; Basal electrical rhythm; ... Clinical electrophysiology; Current source density analysis; Cys-loop receptor; D.

  9. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    The clamp measures the current and other circuitry the voltage; the true power is the product of the instantaneous voltage and current integrated over a cycle. Comprehensive meters designed to measure many parameters of electrical energy ( power factor , distortion , instantaneous power as a function of time, phase relationships, etc.), use ...